Visual signals

The LEDs give important information about the state of the Asyfill. The behavior is presented in Table 10.

Table 10 LEDs behavior

Led

Signal

Color

Meaning

Status

200/800 ms ON/OFF

green

System is ready

solid

blue

System vibrates

200/800 ms ON/OFF

red

System error

200/800 ms ON/OFF

blue

Calibration process on-going

solid for 5 s

green

Calibration done, new parameters applied

Acknowledge reset IP address to default

solid for 5 s

red

Calibration failed, keep old parameters

Power

solid

green

24 VDC on Power input is valid

Push-buttons

The functionality of the two push-buttons is described in Table 11.

Table 11 Push-buttons functionality

Push-button

Action

Effect

Calib.

long press 5 s

Start a calibration procedure

Reset IP

power up while pressed

Reset both calibration and IP settings

Reset IP

long press 5s

Reset IP settings

Note

For more information about the calibration procedure, please refer to calibration procedure.