Visual signals

The LEDs give important information about the state of the Asyfill. The behavior is presented in Table 10.

Table 10 LEDs behavior

Led

Behavior

Meaning

Pattern

Status

200/800 ms ON/OFF

System is ready

led_statud_idling

Solid ON

System vibrates

led_status_vibrate

200/800 ms ON/OFF

System error

led_status_error

200/800 ms ON/OFF

Calibration process on-going

led_status_calib

Solid for 5 s

Calibration done, new parameters applied

Acknowledge reset IP address to default

led_status_solid

Solid for 5 s

Calibration failed, keep old parameters

led_calib_failed

Flashing for 2 s

Reset is confirmed

led_status_confirm

Flashing for 1 s

Booting sequence

led_status_boot

Power

Solid

24 VDC on Power input is valid

led_power_on

Push-buttons

The functionality of the two push-buttons is described in Table 11.

Table 11 Push-buttons functionality

Push-button

Action

Effect

Calib.

long press 5 s

Start a calibration procedure

Reset IP

long press 5 s [1]

Reset IP settings

Reset IP

power up while pressed

Reset both calibration and IP settings

Note

For more information about the calibration procedure, please refer to calibration procedure.