Assembling the container

Caution

Risk of pinching. Do not place your finger between the container and its actuator base.

Caution

Asyfill should not be powered before the installation of the container. Ensure that all cables are unplugged when installing the container.

Table 3 Fixation torque for container screws

Asyfill type

Container screws

Tool required

Fixation torque

Asyfill S 1/2L

M5

5 mm Hex

5.5 Nm

Asyfill M 3/7L

M6

5 mm Hex

9 Nm

Asyfill L 14L

M6

5 mm Hex

9 Nm

Step 1: Place the container onto the actuator base and align the fixation holes.

../../_images/container_s_assembling.png

Step 2: Place the 4 screws and washers loosely in the fixation holes. Tighten them only when all the four screws are in place with the specified torque given in Table 3.

Important

For the Asyfill L, you must tighten the front screws first. Failure to follow this instruction could cause the Asyfill L to malfunction and damage the system

Important

When installing the container, first install the 4 screws and washers loosely. Tighten them only when all the screws are in place. To work properly, we recommend tightening the 4 screws of the container with the specified torque given in Table 3.

../../_images/container_s_screw.png

Important

Modification of the container is not Asyril’s responsibility:

  • Removing material by machining or cutting the container must be avoided; it can impact the rigidity and proper functioning of the system.

  • If modifications are to be made, the container MUST be removed from the actuator base before any drilling operations, see how to remove the container.