Input-Schnittstelle

A standard M8 4-pole interface allows vibrations to be triggered with a 0-10 VDC analog signal.

../../_images/connector_input.png

Abb. 26 Input-Schnittstelle, M8, 4-polig, männlich, Sicht auf das Panel

Pin

Signal

(1)

GND

(2)

digital 24 VDC (nicht verwendet)

(3)

GND

(4)

analog 0-10 VDC

The Input interface of the Asyfill must be connected to one of the Asycube OUT port by using the Analog cable as shown in Abb. 27.

../../_images/connect_asycube.png

Abb. 27 Verbindung mit dem Asycube

How to interface multiple Asyfill

For multi-feeding applications, several Asyfill are generally required. The table below shows the possible variants to connect the Asyfill.

Tab. 9 How to interface multiple Asyfill

With EYE+

Without EYE+

One Asyfill

Comm. 1 / Input interface

Input-Schnittstelle

Two Asyfill

Comm. 1 / Input interface

Input-Schnittstelle

Three Asyfill

Comm. 1

2

Four Asyfill

Comm. 1

2

1 Available from EYE+ version 4.3 and Asyfill version 1.1.
2 Only possible with tailor made integration through a PLC.