Interface Input
A standard M8 4-pole interface allows vibrations to be triggered with a 0-10 VDC analog signal.

Fig. 26 Interface d’entrée, M8 4 pôles, mâle, vue du panneau
Pôle |
Signal |
---|---|
(1) |
GND |
(2) |
digital 24 VDC (non utilisé) |
(3) |
GND |
(4) |
analog 0-10 VDC |
The Input interface of the Asyfill must be connected to one of the Asycube OUT port by using the Analog cable as shown in Fig. 27.

Fig. 27 Connexion avec l’Asycube
How to interface multiple Asyfill
For multi-feeding applications, several Asyfill are generally required. The table below shows the possible variants to connect the Asyfill.
With EYE+ |
Without EYE+ |
|
---|---|---|
One Asyfill |
Comm. 1 / Input interface |
Interface Input |
Two Asyfill |
Comm. 1 / Input interface |
Interface Input |
Three Asyfill |
Comm. 1 |
2 |
Four Asyfill |
Comm. 1 |
2 |
1 Available from EYE+ version 4.3 and Asyfill version 1.1.