You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.12 .Interface Input
A standard M8 4-pole interface allows vibrations to be triggered with a 0-10 VDC analog signal.
![../../_images/connector_input.png](../../_images/connector_input.png)
Fig. 26 Interface d’entrée, M8 4 pôles, mâle, vue du panneau
Pôle |
Signal |
---|---|
(1) |
GND |
(2) |
digital 24 VDC (non utilisé) |
(3) |
GND |
(4) |
analog 0-10 VDC |
The Input interface of the Asyfill must be connected to one of the Asycube OUT port by using the Analog cable as shown in Fig. 27.
![../../_images/connect_asycube.png](../../_images/connect_asycube.png)
Fig. 27 Connexion avec l’Asycube
How to interface multiple Asyfill
For multi-feeding applications, several Asyfill are generally required. The table below shows the possible variants to connect the Asyfill.
With EYE+ |
Without EYE+ |
|
---|---|---|
One Asyfill |
Comm. 1 / Input interface |
Interface Input |
Two Asyfill |
Comm. 1 / Input interface |
Interface Input |
Three Asyfill |
Comm. 1 |
2 |
Four Asyfill |
Comm. 1 |
2 |
1 Available from EYE+ version 4.3 and Asyfill version 1.1.
2 Only possible with tailor made integration through a PLC.